They are bigger than I was able to capture on camera beauty of water heater being in the way.
Is it leading to an outdoor location? Or leading indoor? If so I would just use grey putty, or grey duct seal I think it’s called.
Monkey gunk is what we call it for some reason.
Leading to an indoor wall from a garage.
You have what appears to be a BX cable penetrating and indoor wall to a garage. This needs fire stopping to meet code.
Here is Hilti’s drawing showing the wall assembly and how it can be fire stopped with their products. The optional metal conduit pictured would make it cleaner but also require disconnecting the cable.
Wait until the xenomorph has fully emerged then replace or patch the drywall.
I’d probably go with some sort of split cover plate/flange (or a regular non-split one if you can disconnect it to feed it through). If you have access to a 3D printer, you can make one that way pretty easily. If not, you can probably find one at the hardware store or online that would work.
Yeah definitely use a flanged cover plate but if this goes to an exterior wall, hit the hole with some expanding foam first. Let it dry and then cut the foam flush. Then use the flanged cover.
It’s from a garage to an interior wall. I’m not sure if that would qualify as exterior or not.
I consider “exterior” to mean one side of the wall is air conditioned/heated, and the other side is not. Therefore, an exterior wall has insulation in it. An interior wall is generally hollow.
I’d use some expanding foam if you could feel the air from the other side or see through it. You could also fill that area with silicone (which could also be used to help hold the flanged cover too.